Volume booster maintains pressure supply to air tanks and actuators,and provides great performance where rapid pressure relief is required.
It can be operated remotely using a pilot-operated regulator at a nearby,convenient point.
■VB3 Standard type(Port size:Rc3/8 , Rc1/2 , Rc3/4 , Rc1 , Rc2)
■VB3S Corrosion-resistant type(Port size:Rc3/8 , Rc1/2 , Rc3/4 , Rc1)
Model code Standard type
(Corrosion-resistant type) VB3-04
(VB3S-04) VB3-08
(VB3S-08) VB3-20
Port size 10A 15A 20A 25A 50A
Rc3/8 Rc1/2 Rc3/4 Rc1 Rc2
Applicoble Fluid Dry air after filter passage less than 40μm
Operating pressure Primary side(IN) Max.1.0MPa
Signal pressure 0.02~0.7MPa 0.05〜0.8MPa
Secondary side(OUT) 0.02~0.7MPa 0.05〜0.8MPa
Pressure raito Signal pressure :Secondary side = 1:1
Accuracy Less than ± 0.014MPa(Less than2% FS)
Operating temperature -20~60℃
Mass 1.2kg 3.5kg 9.2kg