0865 735 110

2-Port Small diameter series Sampling Valves ATS2C/MTS2 Konan

Konan sampling valves have been developed under a concept of “sampling from piping systems while maintaining high quality of fluids including
various chemical solutions and ultrapure water used in the pharmaceutical, food manufacturing, and electronic industries.”
With complete fluid accumulation- and contamination-free fluid dividing system, the sampling valves are simply designed to flow and extract
fluids while maintaining pure quality.

■ATS2C Small diameter series Sampling Valves (Air-operated)
■MTS2 Small diameter series Sampling Valves (Manually operated)
Model code 2-Port
Air-operated valve Manually-operated valve
Straight-line piping Straight-line piping
ATS2C MTS2
Size Port size Main port
Sampling port
Orifice size Cv value Orifice size Cv value
8A φ10.5 4.2 φ10.5 2.0 ○ ○
10A φ14.0 7.4 ○ ○
15A φ17.5 11.6 ○ ○
1S φ23.0 20.0 ○ ○
Piping Ferrule clamping, welded, or ISO screw
Fluid pressure Max. 0.4MPa
Operating pressure 0.4~0.5MPa –
Fluid temperature 0~150℃
Ambient temperature 5~60℃
Allowable leakage 0cm3/min(ANR)
Operating frequency Max. 1/s –
Open/close speed
(fluid: air) 8A,10A,15A:0.03s or less
1S:0.035s or less –
Main materials SUS316・SUS316L・TB35H[titanium] Symbol ATS2C symbol
MTS2 symbol
Options Limit switch, proximity switch (air operated type)

.
.
.
.