0865 735 110

Electrostatic potential monitor SP-WATCH (KSD-0110 Kasuga E.W

SP-WATCH® KSD-0110 is an electrostatic potential monitoring device that has an interface to connect our potential sensors EMS-01/EMS-01A/KS-2100 and measures static electricity in real time. It monitors static electricity
 with simple operation and screen display using a touch panel display, and can notify and manage the measurement status using multiple control outputs. SD card support allows you to collect measurement data and alarm history with time stamps.
 The compatible potential sensors EMS-01/EMS-01A have passed the intrinsic safety explosion-proof structure certification when combined with the safety barrier KS-301A, and can be used in hazardous atmospheres.

Features
Up to two channels of potential sensors can be connected, and the measured values of both channels can be displayed in real time and the data can be recorded.
It uses a full-color LCD touch panel with good visibility, making it easy to recognize the current situation and operate intuitively.
Equipped with an SD card slot, it can be used to record measurement data onto an SD card (sold separately), allowing easy data processing on a PC.
Two-stage alarm settings can be made for each channel, and control output can be sent externally.
The combination of the potential sensor EMS-01/EMS-01A and the safety barrier KS-301A enables use in hazardous locations (explosion-proof areas).
The EMS-01A (air purge sensor) applies internal pressure to the inside of the sensor by supplying air, which makes it difficult for powder or paint mist to enter the inside of the potential sensor, enabling highly durable static electricity measurement and monitoring in environments where static electricity measurement was previously not possible.
When using the KS-2100/KS-3101 potential sensor, if the potential sensor fails, it will be displayed immediately on the screen, allowing you to easily determine that an abnormality has occurred in the potential sensor, and a control output can be sent externally.
The vacuum compatible potential sensor KS-3101 can be used in a vacuum environment (see the individual catalog for details).
The display language can be selected from Japanese, English, and Chinese, making it safe to use overseas.
■Screen display example
KSD-0110 screen display example 1.jpg

■Usage example
KSD-0110 usage example.jpg

composition
■ In case of normal environment installation
KSD-0110 configuration diagram 1.jpg

■ When installing in a dangerous location (explosion-proof area)
KSD-0110 configuration diagram 2.jpg

◎Precautions when using in hazardous locations (explosion-proof areas)
When using the potential sensor (EMS-01/EMS-01A) in hazardous locations (explosion-proof areas), a safety barrier (KS-301A) is required. The potential sensor, safety barrier, and dedicated cable are a set that have been certified as explosion-proof, so they must be used as a set.
Explosion-proof structure: Intrinsically safe explosion-proof structure (ia) Explosion-proof symbol: Exia ⅡBT4Ga Certification number: No. TC22115X

specification
■Display device body
Model KSD-0110
Display range EMS-01 0~±20.0kV/0~±50.0kV
EMS-01A 0 to ±20.0kV
KS-2100 0~±2000V/0~±20.0kV
Measurement accuracy ±10% of Reading
Number of Channels 2 channels (max)
Measurement period 100ms, 500ms, 1000ms (1s)
Analog Output Voltage 0 to ±200mV/0 to 500mV (when 50kV range is selected)
Current 4-20mA
Number of alarm settings Maximum 2 settings for each channel (setting value depends on measurement range setting for each channel)
Alarm History Displays the most recent 10 alarms on the alarm summary screen (clears when power is turned off)
Alarm Output Relay contact output when an alarm occurs (independent for each setting and channel)
Setting monitor signal Relay contact output while setting (output during RUN display)
Potential sensor abnormal signal Relay contact output when potential sensor abnormal signal is output (KS-2100/KS-3101 only)
External Measurement Control Signal Measurement ON/OFF by external dry contact signal control
Control output relay Contact capacity: AC250V 5A, DC30V 5A Output format 1a
Display function 4.3-inch TFT LCD with touch panel function
Display language Japanese, English, Chinese (Simplified and Traditional)
Save function Supported media: SD card, up to 32GB (Class10 recommended), FAT32
Data format: .csv (24 hours divided into 6 time zones, 1 file added for each time zone)
power supply AC100V to 240V 50/60Hz
Power consumption 15VA (max)
Ambient temperature and humidity 0 to 40°C, 65% RH or less (no condensation)
ground A type grounding
dust 0.1mg/m2 or less (no conductive dust)
Where to use Indoor safe place
mass Approx. 3.0 kg (excluding potential sensor and safety barrier)
■ Potential sensor (optional)
Model EMS-01
Detection Method Vibration type surface potential sensor
Measurement range 0 to ±20.0kV / 0 to ±50.0kV (set by KSD-0110)
Measurement distance 100mm
cable Dedicated cable sold separately, maximum cable length 90m
Ambient temperature and humidity 0 to 40°C, 65% RH or less (no condensation)
mass Approximately 130g (including supporter)
Model EMS-01A (Air purge sensor)
Detection Method Vibration type surface potential sensor
Measurement range 0 to ±20.0 kV
Measurement distance 100mm
Cable length 5m (can be extended up to 20m)
Air flow rate used 50 to 85 L/min
Ambient temperature and humidity 0 to 40°C, 65% RH or less (no condensation)
mass Approx. 350g (excluding cable)
Dedicated cable
 ・Sensor cable EMS-01-C05: Cable length 5m
 ・Sensor cable EMS-01-C20: Cable length 20m
 ・Extension cable EMS-OP-C04: Cable length specified

Model KS-2100
Detection Method Vibration type surface potential sensor
Measurement range Low range: 0 to ±2000V
High range: 0 to ±20.0 kV
Measurement distance Low range: 10mm
High range: 50mm
Cable length 5m (can be extended up to 100m)
Ambient temperature and humidity 0 to 40°C, 65% RH or less (no condensation)
mass Approx. 100g (excluding cable)
 *Please refer to the separate catalog for the vacuum compatible potential sensor KS-3101.

■ Safety barrier (optional)
Model KS-301A
Included Cable 1.5m with terminal (between KSD-0110 and KS-301A)
Ambient temperature and humidity 0 to 40°C, 65% RH or less (no condensation)
Where to use Indoor safe place
mass Approx. 125g (excluding cable)
■Industrial SD card [2GB] (optional)
 This is an industrial SD card whose operation has been confirmed by our company.

■ Free bushing [with M4 plastic screw] (optional)
 This is used when the KSD-0110 is installed in the control panel and there is a lot of noise coming from the control panel case.

Dimensions and names of each part (dimensions in mm)
■KSD-0110
KSD-0110Fig.jpg

■EMS-01
KSD-0110(EMS-01)Figure.jpg

■EMS-01A

■KS-2100
KSD-0110(KS-2100)Fig.jpg

■KS-301A
KSD-0110(KS-301A)Fig.jpg

.
.
.
.