0865 735 110

weighing indicator Type:PT650D Chimei

 FEATURES
– Apply for all strain gauge load cell;
– Clear and stable 13mm 6 digitals LED display;
– gross weight and net weight can be selected;
– Display step width is selectable of 1, 2, 5, 10, 20 or 50;
– Numeric display “O.L.” when overload;
– Display decimal point is selectable of 4 decimal places;
– Automatic zero tracking;
– Automatically set tare by push button;
– Delta-sigma conversion method;
– Internal resolution is 16,000,000 counts;
– Scale display resolution from 300 to 10,000;
– Conversion rate up to 200 times/sec;
– Software function setting method;
– External on/off switch for function and calibration setting protection;
– Option:
RS232/RS485 input and output port;
Hi/Lo comparator output (opto-couple, dielectric strength 80VDC,
300mA);
Parallel BCD output;
or Analog output;
– Optional software: single material batching control software.

■ Principle of Work

DIGITAL SECTION
1. Weight display : 6 digits LED display
2. Display height : 13mm
3. Annunciators : Gross, Net, Zero, Motion and unit(kg/t)
4. Negative sign indication : “-” on the left most digit
5. Over-range indication : Display “O.L”
6. Maximum capacity : 500 to 100,000
7. Step width : 1, 2, 5, 10, 20 or 50
8. Decimal point : Displays to four different decimal places
ANALOG SECTION
1. Load cell type : All strain gauge load cell
2. Load cell supply : 10VDC±5%, 150mA
3. Output sensitivity : 0.5μV/D to 200μV/D
4. Input resistance : More than 100MΩ at 500VDC between each terminal
5. Zero point adjustment : 0.05mV to 15mV
6. Span stability : ±8ppm/ K of F.S
7. Zero stability : ±(0.4μV±0.006% initial zero offset voltage)/K
8. Non-linearity : Within 0.005% of F.S
9. Conversion method : Delta-sigma
10. Conversion rate : Up to 200 times/sec
11. Internal resolution : 16,000,000
12. Maximum display resolution : 10,000 divisions
13. Comparison cycle : Approx 200 times/sec
4 PT650D instruction manual
14. Dielectric strength : Between input terminal(common/earth/each opto-coupler output/analog output/BCD output), for 1 min, at 500VDC. Between power supply terminal and input terminal(common/earth/each opto-coupler
output/analog output/BCD output), for 1 min, at 1500VAC. OPTION:
15. Analog or BCD output : 0~5V, 0~20mA/4~20mA(selectable), parallel BCD
16. Serial output : RS232 or RS485 option
17. Control output : Four opto-coupler option

■ Technical Parameter

RS232/RS485 SERIAL OUTPUT (OPTION)

1) STANDARD : EIA-RS232/RS485 output
2) STREAM FROMAT
Data bit = 7
Parity bit = 1 (even)
Stop bit = 1
Code = ASCII code
Baud rate = 2400, 4800, 9600, 19200
Delimiter = CR/LF
3) RS232/RS485 MODE
a) Command mode: After receiving the command word from
RS232/RS485 port, the indicator will carry out
the appropriate action, those command valid
only for RS232/RS485 port.
Command: READ<CR><LF> : request measured data
TARE<CR><LF> : request TARE weight setting
KEY<CR><LF> : key protection ON or OFF
ZERO<CR><LF> : request ZERO value
Example: Read command (READ<CR><LF>) is
“52H, 45H, 41H, 44H, 0DH, 0AH” in ASCII code.
b) Continuous mode: The data will be transferred constantly without any
input command to the RS232/RS485 port.

Hi/Lo COMPARATOR OUTPUT(OPTION)
1) Hi/Lo output : HH, Hi, Lo or LL
2) Max. capacity : 80VDC, 300mA
2-6 BCD OUTPUT(OPTION)
1) BCD output : Parallel BCD output
2) BCD output level : TTL or open collector
2-7 ANALOG OUTPUT(OPTION)
1) Analog output mode : 0~5V/0~20mA/4~20mA
2) The excitation current will be reduced to 120mA if the 0~20mA/4~20mA output board is used.
2-8 INPUT(BUILT-IN)
1) Input : IN1, IN2 or IN3
2) Input mode : Passive switch
3) Input contact time : 30 ms

PT650D WEIGHING INDICATOR INSTRUCTION MANUAL ⇓

.
.
.
.