The MA-920 is a small area flowmeter that measures and outputs minute flow rates of various liquids and gases. It is an advanced microflow meter that combines many years of manufacturing know-how of area flow meters with state-of-the-art electronics technology.
In the past, there were various difficulties in improving the accuracy of area flow meters for micro-flow rates, such as machining accuracy, friction acting on floats, and non-linear characteristics.
In the MA-920, these error factors are automatically corrected by a microprocessor equipped with calibration data, enabling high-precision measurement in the minute flow range. The 2-wire DC4 – 20mA wiring scheme makes it extremely easy to construct on site.
Catalogs & Pamphlets
-
MA-920
* The information is subject to change without notice due to product improvement.
forte
- Covers a small flow range with a minimum flow rate of 0.6 ~ 3 L/h (water)
- Magnetic sensor detection method eliminates hysteresis, achieves high accuracy and high reproducibility
- Easy-to-read LCD digital display
- 2-wire, DC 4 ~ 20 mA output
- Exd II CT6, explosion-proof structure for hydrogen zero encirclement. There is no problem using it in hazardous areas
- No damper required even in gas specifications
Standard Specifications
Measurement target | Liquids in general, gases in general (not suitable for liquids containing solids)
However |
---|---|
caliber | 1/4, 3/8, 1/2, 3/4, 1 10A, 15A, 20A, 25A (meter size) 1/2, 3/4, 1 |
Flow range |
Liquid measurement (water equivalent) * The flow rate range varies depending on the viscosity.
Max. 60 ~ 600 L/h Min. 0.6 ~ 3 L/h Gas measurement (air equivalent) |
Fluid pressure | 2.94 MPa Max. for high pressure 19.6 MPa Max. (Body material is SUS316) In the case of flange connection, within the flange standard |
Process Connections | RC screws, JIS10KFF flanges (optional) Various screws such as NPT, non-JIS10KFF flanges |
Measurement accuracy | Full scale 10 L/h (water) or more ±2% F.S. Full scale less than 10 L/h (water) ±3% F.S. Full scale 100 L/h (nor) (air) or more ±2% F.S. |