0865 735 110

Air Filters AF2 Konan

Drain fluids in the pneumatic lines may increase piping corrosion resistance, and hinder the function of controls in the line, finally lead to accidents.
Be sure to use air filters to remove drain fluids from the line and prevent problems.

■AF2/AF21 Standard type(Port size:Rc1/8 , Rc1/4 , Rc3/8 , Rc1/2 , Rc3/4 , Rc1 , Rc1 1/4 , Rc1 1/2 , Rc2 , Rc2 1/2 , 80A , 100A)
■AF2S/AF21S Corrosion-resistant type(Port size:Rc1/4 , Rc3/8 , Rc1/2 , Rc3/4 , Rc1 , Rc1 1/4 , Rc1 1/2 , Rc2 )
■AF2P/AF21P Panel-mount type(Port size:Rc1/4 , Rc3/8 , Rc1/2 , Rc3/4 , Rc1)
■AF2PS/AF21PS Panel-mount・Corrosion-resistant type(Port size:Rc1/4 , Rc3/8 , Rc1/2 , Rc3/4 , Rc1)
Model code Standard type AF2-02
Port size 6A 8A
Rc1/8 Rc1/4
Effective sectional area 7mm2(Filter rating=5μm)
Operating pressure 0~1.0MPa
Proof pressure 1.5MPa
Operating temperature -20~60℃
Mass 0.19kg
Model code Standard type
(Corrosion-resistant type) AF21-04
(AF21S-04) AF2-08
(AF2S-08) AF2
(AF2S) AF2
Panel-mount type
(Corrosion-resistant type) AF21P-04
(AF21PS-04) AF2P-08
(AF2PS-08) –
Port size 8A 10A 15A 20A 25A 32A 40A 50A 65A 80A
フランジ 100A
フランジ
Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1 Rc1 1/4 Rc1 1/2 Rc2 Rc2 1/2
Effective sectional area General purpose 40mm2 68mm2 90mm2 171mm2 190mm2 480mm2 655mm2 1060mm2 1450mm2 1800mm2 2500mm2
Instrumentation 28mm2 30mm2 40mm2 76mm2 77mm2 190mm2 190mm2 300mm2
Operating pressure 0~1.0MPa
Proof pressure 1.5MPa
Operating temperature General purpose:-20~60℃ 
Heat-resistant:5~100℃ 
Freeze-resistant:-40~45℃ -20~60℃
Mass 0.58kg 0.62kg 0.6kg 12.0kg 22.0kg 28.0kg 39.0kg 50.0kg
●Above values of mass exclude weight of mounting bracket.
●Refer to catalog for details.

.
.
.
.