AP-AB1218 Air Source Anti-Electric Shock Pulse AC Ion Bar
Video
Picture
Share:
1.PRINCIPLES:
2.FEATURES:
3.SPECIFICATION:
4.WORKING MODE:
5.ELECTROSTATIC ELIMINATION EFFECT:
6.PRODUCT SIZE:
1.PRINCIPLES:
AP-AB1218 ionizes air molecules by using DC high voltage acting on coupled electrode needle to generate corona discharges, producing large amount of positive and negative air ions and transferring to the surface of objects through compressed air to reach high efficiency of static elimination.
DOWNLOAD FILE OF AP-AB1218:
ap-ab1218-high-efficiency-electroshock-proof-ion-bar-new.pdf
ap-ab1218-high-efficiency-electroshock-proof-ion-bar-new.pdf |
2.FEATURES:
- Easy Installation(Stainless steel mounting angle provided for different installation environment)
- Electric shock proof(Prevent human from electric shock)
- Intake throttle valve(The specification is Φ8-G1/8 grey)
- Working status visualization(Red light alarm when high voltage abnormal)
- Network Monitoring(Wired network communication realisable and monitor the working status of the ion bar)
6. CE Certified(Electromagnetic protection function)
3.SPECIFICATION:
Model | AP-AB1218 |
Input voltage | DC 24V |
Input current | < 600mA |
Power | 10W |
Working voltage | DC±5KV |
Ion emission | Pulse AC |
Emitter electrode | Tungsten alloy |
Discharge structure | Resistance coupling |
Output frequency | 0.1,1,3,5,10,20,30,50,70,80,100Hz;( ex-work setting:50Hz) |
Duty ratio | 10%—90% |
Discharge range | L*W*H:{300-3000mm)}*300*1000mm |
Installation distance | 100 → 1000mm |
Ion balance | ≤ |±30V|(AVG) |
Discharge time | ≤ 2S |
Alarm indication | High voltage alarm indicator(Green light: Normal working, Red light : Abnormal high voltage ) |
Communication
function |
RS485 |
Signal output | Collector open circuit 50V/100mA |
Air pressure | ≤ 0.6MPa |
Intake throttle valve connector | Φ8-G1/8 Grey |
Working temperature | 0℃ -50℃ |
Working humidity | < 70% |
Dimensions | L*W*H:{300-3000mm}*35*64.5mm |
Bar material | Flame retardant PVC、AL、SUS |
Packaging
accessories |
180°rotatable mounting bracket,M5-12*12*4 square nut |
Warranty | 1Year |
Certification | CE |
4.WORKING MODE:
The pulsed AC method alternately applies a high voltage of “+” and “-” to each electrode needle, generating ions of two polarities. Compared with the industrial frequency AC method, the ion generation rate is higher, and the electrostatic elimination capability can be utilized at both near and far distances. In addition, the discharge frequency can be adjusted to extend the elimination distance. The positive and negative ion output ratio can be adjusted for intelligent control.
5.ELECTROSTATIC ELIMINATION EFFECT:
6.PRODUCT SIZE: