0865 735 110

Digital proportional directional valve HYGS HOYAE

If it exceeds the range of specified technical parameters when using, please consult Huaye Company

Model HYGS    82A
Installation location Optional, horizontal installation is recommended
Storage Temperature (°C) -20 to 80
Ambient temperature (°C) -10 to 60

Hydraulic parameters

Working pressure (bar) Port A, P 315
Port T 210
Rated flow p=10 bar (L/min) Specification 5 5
Specification 8 8
Working medium Mineral oil according to DIN 51 52 (HL, HLP);

If you are using other fluids, please contact us!

Medium temperature range (°C) -20~+80(+40~+50 preferred)
Media viscosity range (mm2/s) 20~-380 (30-46 preferred)
Hysteresis (%) ≤1
Repeatability (%) ≤1
Sensitivity (%) ≤0.2
Degree of contamination The maximum allowable contamination level of the oil is NAS1638 level 9,

Recommended filter accuracy (20≤δ≤50)

Electrical parameters

Current (A) Resistance (Ω) Inductance (mH) NUMBER OF LEADS(NO.)
3 0.8 2.4 4
.
.
.
.