Operating voltage UB | 24VDC +40% -20% |
—The upper limit is UB(t)max | 35V |
—The lower limit value is UB(t)min | 19VC |
Power Consumption PS | <45VA |
Current consumption I | <2A |
The setting value is entered into an AI-type Ue | ±10V,Re>50kΩ |
The setpoint input is Fi-type IE | 4-20mA,Re<200Ω |
The maximum output current is Imax | 2.5A R(20)=2Ω |
The actual value outputs U | ±10V, ±5%; Imax=2mA |
Slope time t | 0-5 seconds, adjustable |
Form of connection | Socket: DIN43650-AM2 |
Plug: E DIN4363-BF6-3/PG11 | |
Allowable operating temperature range | -20-80℃ |
Storage temperature range | -25-85℃ |
Ingress protection | IP65 press DIN40050 |
Weight m | 0.14kg |