0865 735 110

Panel Indicators Tokyo Keiso IR1700

Flow Measuring Instruments
Panel Indicators

Panel Indicators

The IR1700 is an indicator and totalizer for flow meters. It is connected to a pulse output type flow meter to display the switching of instantaneous flow rate and integrated flow rate and to output an alarm. Each setting information, such as scaling and preset values, can be changed arbitrarily by operating the keys on the panel surface. It has a built-in 12V power supply for the sensor and can be combined with a 3-wire pulse output sensor. The compact housing of DIN48×24 is ideal for small control panel mounting.

Catalogs & Pamphlets

* The information is subject to change without notice due to product improvement.

Standard Specifications

Display function Indicator: red LED 5-digit display, character height; 7mm
Instantaneous measurement display:
4-digit LED (variable decimal point) Display
range 0.001 ~ 9999
Measurement accuracy ±0.05% rdg. ±1digi
Low Cutoff 1 ~ 29% Variable
Display Period Average at 0.1 ~ 99.9 sec
Totalization measurement display:
5-digit LED (variable decimal point)
Display range 0 ~ 99999
Display accuracy ±0
Accumulation rate 1 ~ 180000 counts/h
Low cutoff Apply
instantaneous display settings Over display You can
select the following displays. ・ Display digit flashing (flashing at 99999 and stopping accumulation)
・Endless display (continuous accumulation from zero)
・Digit shift (display × 10 times and continue accumulation)
Instantaneous / Totalization display in the event of an input abnormality When the
input signal exceeds 150% F.S., the least significant digit flashes.
LED lamps (3 on the front of the panel)
1 (red): Lights up when the alarm output OUT1 is ON
2 (Red): Lights up when the alarm output OUT2 is turned on
T (green): Lights up when the total is displayed
input Pulse input (in combination with pulse output sensor):
• NPN open collector pulse or contact pulse (non-voltage contact)
• Voltage pulse
External input:
NPN The following functions can be selected by receiving an open collector input or a contact input.
・Reset input: Reset the total counter or alarm with ON input
・Prohibited input: Sensor input is prohibited with ON input (forced zero)
・Hold input: Hold the current display value with ON input
output Alarm output:
Instantaneous measurement / Totalization measurement (cannot be used together)
・NPN open collector
power DC12V、50mA max.
Degree of protection Front panel IP66 (Case body IP20 equivalent)

.
.
.
.