0865 735 110

Pressure gauge NS63/100 ECOnomic for food/pharmaceutical/biotechnology Type series BH5…ECO LABOM

Pressure gauge NS63/100 ECOnomic
for food/pharmaceutical/biotechnology, Type series BH5…ECO

 

Features
■ High quality case with bajonet ring NS 63/100
■ Nominal ranges 0…2,5 to 0…25 bar, -1…1,5 bar to -1…15 bar
■ Case and measuring element of stainless steel
■ Degree of protection IP 65
■ Accuracy class 1.6/1.0 as per EN 837-1
■ Flush mounted diaphragm
■ Small temperature error by means of reduced-volume
measuring element
■ Temperature range up to 140 °C
■ EAC declaration (upon request)

Options
■ Approvals/Certificates – Certificate of measuring equipment for Russian
Federation – Material certificate per EN 10204 – Calibration certificate per EN 10204
■ Case with liquid filling
■ Hygienic design
■ Autoclavable
■ EAC declaration (upon request)
Application
The pressure gauge NS 63/NS 100 ECOnomic is suitable
for the use in applications in the food and pharmaceutical
industry and biotechnology.
Constructional design / case
Design:
Nominal size:
Degree of
High quality case with bayonet ring,
material: st.steel mat.-no. 1.4301 (304)
ventilation valve, material: PUR
NS 63 or NS 100
IP 65
Measuring
element:
System filling:
Bourdon tube – c-type
NS 63:
NS 100:
screwed
pressure connection weld
ed to process connection
Synthetic oil, free of silicone FD1, FDA
listed
protection per
EN 60529:
Case filling:
Atmosph.
pressure com
pensation:
Case seal:
Window:
Movement: stainless steel segment
Option:
Glycerine-water
Further liquid fillings upon request.
Via ventilation valve.
Material gasket: NBR
Non-splintering laminated glass.
Option: Non-splintering plastic (Macrolon)
Scale:
Pointer:
Pure aluminium, white with black inscrip
tion.
Option: with red marking or with fixed
reference pointer
Special scale upon request
NS 63:
NS 100:
pure aluminium, black
pure aluminium, black,
with micro adjustment for
zero point correction
Data sheet D2-028-5 Rev. 1I8

Data sheet D2-028-5 Rev. 1I8
Weights: NS 63 without filling: approx. 0.5
kg
NS 100 without filling approx. 1.0
kg
NS 63 with filling: approx. 0.7
kg
NS 100 with filling: approx. 1.3
kg

Process connection
Design: Via diaphragm seal technology, see order
details and product group D5

Material wetted parts
Membran: See order details
Nominal range
See order details, further ranges upon request

Overload pro
tection
Standard: 1.3 times

Accuracy
Accuracy
class:
per EN 837-1

NS 63: class 1.6
NS 100: class 1.0

Temperature
influence:
Max. ± 0.4% / 10K of measuring span per
EN 837-1

Process
temperature
influence:
depending on active diaphragm diameter

dM 15.5 mm upon request *
dM 22.6…24 mm ≤ 25 mbar / 10 K *
dM 27…30 mm ≤ 20 mbar / 10 K *
dM 34…36 mm ≤ 8 mbar / 10 K *
dM 40…46 mm ≤ 5 mbar / 10 K *
dM 51…58 mm ≤ 2 mbar / 10 K *

* A detailed calculation of accuracy can be
submitted upon request.

Hygienic design
The wetted surfaces made of stainless steel are executed
according to EHEDG Doc.8 and ASME BPE SF3
(Code: HY).
We guarantee the following surface roughness values:

Diaphragm foil: Ra ≤ 0.38 µm
Laser welds: Ra ≤ 0.76 µm
Turned parts: Ra ≤ 0.76 µm

Further versions of hygienic design upon request.

Autoclav.
design:
Autoclavable without case filling, only.
Please remove the ventilation valve before
autoclaving.

Temperature ranges
without filling with filling
Ambient: -10…50 °C -10…50 °C
Media: 0…140 °C 0…140 °C
Storage: -20…60 °C -20…60 °C
Autoclave temperature: 130 °C for 1 hour (without filling)

Extended temperature range (-20…60 °C) optional.

The maximum values can be restricted by the following
parameters:

■ diaphragm size
■ measuring range
■ pressure transmission fluid

Tests and certificates
■ EAC declaration (upon request)
■ Certificate of measuring equipment for Russian Federa
tion

Information on other models see order details or upon
request.

Data sheet D2-028-5 Rev. 1I8
Dimensions

All dimensions are in mm

Sanitary pipe connection with union nut per DIN 11851

DN PN dM b G
25 40 27 16 Rd.52×1/6“
32 40 34 16 Rd.58×1/6“
40 40 40 16 Rd.65×1/6“
50 25 51 17 Rd.78×1/6“

Aseptic screw joint collar connection with union nut per
DIN 11864-1 type A

DN PN dM G
25 40 24 Rd.52×1/6“
32 40 30 Rd.58×1/6“
40 40 34 Rd.65×1/6“
50 25 48 Rd.78×1/6“

Clamp connection per DIN 32676 model A (metric) for pipes per
EN 10357 (DIN 11850)

DN PN dM b D
25 25 22.6 14 50.5
32 25 27 12 50.5
40 25 34 12 50.5
50 16 46 14 64

Clamp connection per DIN 32676 model B (OD, ISO) for pipes per DIN
EN ISO 1127

DN PN dM b D
26.9 25 22.6 14 50.5
33.7 25 27 12 50.5
42.4 25 34 12 64
48.3 16 46 14 64

Clamp connection per DIN 32676 model C (Tri-Clamp) for pipes per
ASME BPE

DN PN dM b D
3/4″ 25 15.5 15 25
1“ 25 22.6 14 50.5
1 1/2“ 25 34 12 50.5
2“ 16 46 14 64

Clamp connection per ISO 2852 for pipes per ISO 2037

DN PN dM b D
25 16 22.6 14 50.5
38 16 34 12 50.5
51 16 46 14 64

Varivent connection

DN / Zoll PN dM A D
25 / 1“ 25 40 66 50
40-80/ 1 1/2 “- 3“ 25 58 84 68
100 /4“ 20 58 84 68
125 / 6“ 10 58 84 68

LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany
Phone: +49 4408 804-0 Fax: +49 4408 804-100 e-mail: info@labom.com www.labom.com
Order details

Pressure gauge ECOnomic for food/pharmaceutical/biotechnology,
Type series BH5… ECO NS 63/100
Order details BH5…
BH5100 ECO
case design
IP 65, NS 63
without liquid filling
process connection bottom
BH5110 ECO process connection at back
BH5120 ECO
with liquid filling
process connection bottom
BH5130 ECO process connection at back
BH5200 ECO
case design
IP 65, NS 100
without liquid filling
process connection bottom
BH5210 ECO process connection at back
BH5220 ECO
with liquid filling
process connection bottom
BH5230 ECO process connection at back

A55
nominal range [bar] 0…2,5
A56 0…4
A57 0…6
A58 0…10
A59 0…16
A60 0…25
A88 -1…1,5
A89 -1…3
A90 -1…5
A91 -1…9
A92 -1…15

K102
process connection 1
material: ASTM (316L)
sanitary pipe connection with union
nut per
DIN 11851
DN 25
K103 DN 32
K104 DN 40
K105 DN 50
K124
Clamp connection per ISO 2852 for
pipes per ISO 2037
DN 25 (1“)
K126 DN 38 (1 1/2″)
K127 DN 51 (2″)
K144
Clamp connection per DIN 32676,
model A (metric) for pipes per EN
10357 (DIN 11850)
DN 25
K146 DN 32
K147 DN 40
K148 DN 50
K213
Clamp connection per DIN 32676,
model B (OD, ISO) for pipes per
DIN EN ISO 1127
DN 26.9
K214 DN 33.7
K215 DN 42.4
K216 DN 48.3
K134
Clamp connection per DIN 32676,
model C (Tri-Clamp) for pipes per
ASME BPE
DN 3/4″ 2,3
K136 DN 1″
K137 DN 1 1/2″
K138 DN 2″
K152
Varivent connection
D = 50 for Varivent case DN 25 and 1″
K153 D = 68 for Varivent case DN 40… DN 125 and 1 1/2″ …. 6″
K80 screw-in thread HYGIENIC G 1 A rotatable, gasket-free
surface roughness
(wetted parts)
standard
HY Hygienic version as per EHEDG Doc.8 and ASME BPE SF3

Additional features (to be indicated if required)
T2
marking
on scale (please specify)
T3 fixed reference pointer (please specify)4
W1020 material certificate per EN 10204-3.1, wetted parts
W1204
calibration certificate
per EN 10204-3.1, 3 measuring points
W1201 per EN 10204-3.1, 5 measuring points
W2673 certificate of measuring equipment for Russian Federation
W4073 autoclavable (130 °C for 1 hour) 5
W4090 extended temperature range
Order code (example): BH5200 ECO – A56 – K102 – …
1 further process connections (diaphragm seals) upon request
2 for case NS 63 only
3 for a function calculation and optimim system design it is necessary to specify the operation temperature
4 for case NS 100 only
5 for case without liquid filling and single strength glass only

.
.
.
.