Order number
6ES7331-7KF02-0AB0
Properties
- 8 inputs in 4 channel groups
- Programmable measurement type at each channel group
- – Voltage
- – Current
- – Resistance
- – Temperature
- Programmable resolution at each channel group (9/12/14 bits + sign)
- Any measuring range selection per channel group
- Programmable diagnostics and diagnostic interrupt
- Programmable limit value monitoring for 2 channels
- Programmable hardware interrupt when limit is exceeded
- Electrically isolated to CPU and load voltage (not for 2-wire transducers)
Resolution
The resolution of measured values is directly dependent of the selected integration time. In other words, the longer the integration time for an analog input channel, the higher the resolution of a measured value.
Diagnostics
For information on diagnostics messages at the “group diagnostics” parameter, refer to chapter Diagnostic messages of analog input modules.
Hardware interrupts
Hardware interrupts for channel groups 0 and 1 can be programmed in STEP 7. However, set a hardware interrupt only for the first channel of a channel group, that is, either at channel 0, or at channel 2
Terminal assignment
The diagrams below show various wiring options The input impedance depends on the setting of the measuring range module, see table Measurement types and ranges.
Wiring: Voltage measurement

Figure: Block diagram and wiring diagram
Measuring range module settings
|
Measuring range |
Measuring range module setting |
|---|---|
|
± 80 mV ± 250 mV ± 500 mV ± 1,000 mV |
A |
|
± 2.5 V ± 5 V 1 V to 5 V ± 10 V |
B |
Wiring: 2-wire and 4-wire transducers for current measurement

Figure: Block diagram and wiring diagram
|
Note The interconnection between MANA and M- (terminals 11, 13, 15, 17, 19) is not required when using grounded 4-wire transducers with non-isolated supply. |
Measuring range module settings
|
Measuring range |
Measuring range module setting |
|
|---|---|---|
|
2-wire transducer |
4 mA to 20 mA |
D |
|
4-wire transducer |
± 3.2 mA ± 10 mA 0 mA to 20 mA 4 mA to 20 mA ± 20 mA |
C |
![]() |
Caution Measuring range module in “Current” positionAny voltage measurement will destroy the measuring range module if “current” measuring mode is set. |
Wiring: 2-, 3- and 4-wire connection of resistance transducers or thermoresistors
|
① |
4-wire connection |
|
② |
3-wire connection, no compensation for line resistors |
|
③ |
2-wire connection, no compensation for line resistors |
Figure: Block diagram and wiring diagram
Measuring range module settings
|
Measuring range |
Measuring range module setting |
|
|---|---|---|
|
150 Ω 300 Ω 600 Ω |
A |
|
|
Thermoresistor |
Pt 100 Klima Ni 100 Klima Pt 100 Standard Ni 100 Standard |
A |
|
Note
|
Wiring: Thermocouples with external compensation
Insert a bridge between Comp+ and MANA when using the internal compensation.

Figure: Block diagram and wiring diagram
Measuring range module settings
|
Measuring range |
Measuring range module setting |
|
|---|---|---|
|
Thermocouple TC-I (internal comparison) (thermal voltage measurement) Linearization is ignored |
Type N [NiCrSi-NiSi] Type E [NiCr-CuNi] Type J [Fe-CuNi] Type K [NiCr-Ni] Type L [Fe-CuNi] |
A |
|
Thermocouple TC-E (external comparison) (thermovoltage measurement) Linearization is ignored |
||
|
Thermocouple |
Type N [NiCrSi-NiSi] Type E [NiCr-CuNi] Type J [Fe-CuNi] Type K [NiCr-Ni] Type L [Fe-CuNi] |
A |
|
Thermocouple |
||
|
Note
|
Technical specifications
|
Technical specifications |
||||
|---|---|---|---|---|
|
Dimensions and weight |
||||
|
Dimensions W x H x D (mm) |
40 x 125 x 117 |
|||
|
Weight |
approx. 250 g |
|||
|
Module-specific data |
||||
|
Supports isochronous mode |
No |
|||
|
Number of inputs
|
8 4 |
|||
|
Cable length
|
max. 200 m max. 50 m at 80 mV and with thermocouples |
|||
|
Voltages, currents, electrical potentials |
||||
|
Rated electronics supply voltage L +
|
24 V DC Yes |
|||
|
Transducer power supply
|
max. 60 mA (per channel) Yes |
|||
|
Constant current for resistive transducers |
typ. 1.67 mA (pulsed) |
|||
|
Electrical isolation
|
Yes Yes |
|||
|
Maximum potential difference
|
typ. 2.5 V DC (> 2.3 V DC)
typ. 2.5 V DC (> 2.3 V DC) |
|||
|
Isolation test voltage |
500 V DC |
|||
|
Current consumption
|
max. 50 mA max. 30 mA (without 2-wire transducer) |
|||
|
Power loss of the module |
typ. 1 W |
|||
|
Generation of analog values |
||||
|
Measuring principle |
Integrating |
|||
|
Integration/conversion time/resolution (per channel) |
|
|||
|
Yes |
|||
|
2.5 |
162/3 |
20 |
100 |
|
3 |
17 |
22 |
102 |
|
Additional conversion time for resistance measurement, in ms or |
1 |
1 |
1 |
1 |
|
additional conversion time for wire-break monitoring in ms or |
10 |
10 |
10 |
10 |
|
additional conversion time for resistance measurements and wire-break monitoring in ms |
16 |
16 |
16 |
16 |
|
9 bits |
12 bits |
12 bits |
14 bits |
|
400 |
60 |
50 |
10 |
|
24 |
136 |
176 |
816 |
|
Measured value smoothing |
none |
|||
|
Interference frequency suppression, error limits |
||||
|
Interference frequency suppression at F = n (f1 ± 1 %), (f1 = interference frequency) |
||||
|
> 70 dB > 40 dB |
|||
|
Crosstalk between inputs |
> 50 dB |
|||
|
Operational limit (across entire temperature range, relative to the measurement range end value in the selected input range) |
||||
|
80 mV 250 mV to 1,000 mV 2.5 V to 10 V |
± 1 % ± 0.6 % ± 0.8 % |
||
|
3.2 mA to 20 mA |
± 0.7 % |
||
|
150 Ω; 300Ω; 600 Ω |
± 0. 7 % |
||
|
Types E, N, J, K, L |
± 1. 1 % |
||
|
Pt 100/Ni 100 |
± 0. 7 % |
||
|
|
Pt 100 Klima |
± 0. 8 % |
||
|
Basic error limit (operational limit at 25 °C, relative to the measurement range end value in the selected input range) |
||||
|
80 mV 250 mV to 1,000 mV 2.5 V to 10 V |
± 0.7 % ± 0.4 % ± 0.6 % |
||
|
3.2 mA to 20 mA |
± 0.5 % |
||
|
150 Ω; 300 Ω; 600 Ω |
± 0.5 % |
||
|
Types E, N, J, K, L |
± 0.7 % |
||
|
Pt 100/Ni 100 |
± 0.5 % |
||
|
|
Pt 100 Klima |
± 0.6 % |
||
|
Temperature error (relative to input range) |
± 0.005%/K |
|||
|
Linearity error (relative to input range) |
± 0.05 % |
|||
|
Repeat accuracy (in settled state at 25 °C, relative to input range) |
± 0.05 % |
|||
|
Temperature error of internal compensation |
± 1 % |
|||
|
Status, interrupts, diagnostics |
||||
|
Interrupts
|
programmable Channels 0 and 2 programmable |
|||
|
Diagnostic functions
|
programmable red LED (SF) supported |
|||
|
Encoder selection data |
||||
|
Input ranges (rated values) / input impedance |
|
|||
|
± 80 mV ± 250 mV ± 500 mV ± 1,000 mV ± 2.5 V ± 5 V 1 V to 5 V ± 10 V |
10 MΩ 10 MΩ 10 MΩ 10 MΩ 100 kΩ 100 kΩ 100 kΩ 100 kΩ |
||
|
± 3.2 mA ± 10 mA ± 20 mA 0 mA to 20 mA 4 mA to 20 mA |
25 Ω 25 Ω 25 Ω 25 Ω 25 Ω |
||
|
150 Ω 300 Ω 600 Ω |
10 MΩ 10 MΩ 10 MΩ |
||
|
Types E, N, J, K, L |
10 MΩ |
||
|
Pt 100, Ni 100 |
10 MΩ |
||
|
Maximum voltage at voltage input (destruction limit) |
max. 20 V, continuous 75 V for the duration of max. 1 s (duty factor 1:20) |
|||
|
Maximum current at current input (destruction limit) |
40 mA |
|||
|
Wiring of the signal transmitters |
using a 20-pin front connector |
|||
|
supported |
|||
as 2-wire transducer as 4-wire transducer |
supported supported |
|||
with 2-wire connection |
Supported, cable resistances are not compensated |
|||
|
with 3-wire connection |
Supported, cable resistances are not compensated |
|||
|
with 4-wire connection |
Supported, cable resistances are compensated |
|||
|
max. 820 Ω |
|||
|
Characteristics linearization
|
programmable Types E, N, J, K, L |
|||
|
Pt 100 (Standard and Klima range) Ni 100 (Standard and Klima range) |
|||
|
Temperature compensation
|
programmable supported |
|||
|
supported |
|||
|
supported |
|||
|
degrees Centigrade |
|||
![]() |