| Control system |
| Control system |
Zero-cross |
|
|
| Rating |
| Rated current |
20A, 40A |
| Rated input voltage |
5 to 24V DC |
| Input current consumption |
7mA or less (at 25 ) |
| Rated load voltage |
100 to 240V AC |
| Surge ON current tolerance |
220A (SA-420-Z)
440A (SA-440-Z) |
| Applicable load |
Resistive load |
| Operating time |
1/2 cycle of the load current + 1ms or less |
| Restoration time |
1/2 cycle of the load current + 1ms or less |
| Output ON voltage drop |
1.6V (RMS) or less (when applying max. load) |
| Leak current |
10mA or less, at 200V AC |
|
|
| General structure |
| Mounting |
Both DIN rail and panel mountable |
|
|
| Insulation, Dielectric strength |
| Insulation resistance |
100M or more, at 500V DC
Between Input/Load terminals, Between terminals – Heat sink |
| Dielectric strength |
3000V AC for 1 minute
Between Input/Load terminals, Between terminals – Heat sink |
|
|
| Others |
|