0865 735 110

Speedmeter/Counter [Switchable] SPD-4801

Specifications 

Name
Model
Measuring method
Speedmeter/Counter [Switchable] SPD-4801
PeriomaticTMB method Cycle calculation method
Input  Number of input points
Input frequency
Input resolution
Input Signal
Input method
1 point
0.0006Hz to 1.0MHz
Approx. 10.4ns (96MHz)
5V logic, zero cross, NPN open collector, 12V logic, input customized signal
Single-phase signal
[*] General-purpose
input option
Input Level and Sensitivity
5V logic

Zero-cross
NPN open collector
12V logic
Customized input
Trigger level
2.5V
0V
2.5V
6V
0-9.0V
in 10mV units
Hysteresis
±0.4V
±0.03V
±0.4V
±0.4V
Small:±0.03V, Medium : 0.4V,
Large: ±1.3V, trigger level 4.7V or lower/ ±2.6V, trigger level 4.7V or higher
Input pulse
Input resistance

Input withstand voltage

[Small] [Medium] 0.2 μs or more   [Large] 0.3 μs or more, for both H and L levels
5V logic, zero cross, NPN open collector, and Input customized signal (trigger level 4.7V or lower): 10kΩ
12V logic, input customized signal (trigger level 4.71V or higher): 5kΩ
±30V  *Inputs and outputs are not insulated for the general-purpose input option.
[D] Line driver
input option
Input signal
Input withstand voltage
Recommended line driver
Termination resistance
Line driver signal
±25V (differential voltage)
Equivalent to AM26LS31
300Ω (standard specification)  *Input and output are isolated for the line driver input option.
[W] 2-Phase(A/B)
input option
Input Level and Sensitivity
5V logic

Zero-cross
NPN open collector
12V logic
Customized input
Trigger level
2.5V
0V
2.5V
6V
0 / 2.5 / 6V
Hysteresis
±0.4V
±0.03V
±0.4V
±0.4V
Small:±0.03V, Medium : 0.4V
Input pulse
Input resistance
Input withstand voltage
[Small] [Medium] 0.2 μs or more, for both H and L levels
10kΩ
±30V
Input low-pass filter
Trigger edge
Input withstand voltage
Input connector
Sensor Power supply output[Option]
Select from OFF, 500Hz, 5kHz, 120kHz, or 800kHz
Fall
±30V
Terminal block 7.62mm pitch M3 free terminal screw
[H] DC +12V±5% 60mA max / [L] DC +5V±5% 150mA max
Calculation Measurement mode
Calculation rate
Frequency divider ratio
Output moving average
Dynamic PredictiveTM
Control input
[Setting contents] [Operation Method] [Data communication]

Low cut function

Velocity meter/Frequency meter/Period meter (seconds only) /Counter
Set the reference pulse number, reference change, and speed unit time with respect to the input frequency.
1 to 60000
1 to 99
8 levels (including continuous and stop prediction)
None or 1 point (depending on model), [D2] Option to add 2 points.
Set a function for each control input (CTL) and control from outside
Functions: hold (current/max./min. value, max. fluctuation range), zero/span shift (Count), stop Count (stop, start)
Control input ON logic (normally open, normally closed) can be set
ON when control input (CTL*) pin (ON logic) is shorted (open) to GND; setting is reflected when open (shorted).
Command control is possible via communication (USB, CAN, RS-485)
Commands set via communication cannot be released by terminal input. Reset execution is always required.
Low cut function Stop judgment at a speed lower than the set value
Display Display Color
Indicator (Numerical Display)

Decimal point position
Display update time
Display accuracy
Indicator (3 round LEDs)

[Standard] SPD-4801 Red LED / [Option] SPD-4801-G Green LED
6-digit, 7-segment LED Character height 14.2mm / Display range:-199999 to 999999
Polarity indication: Reverse rotation -Lighted / Over indication: OL / Zero indication: Leading zero suppress
Semi-fixed Decimal point position is set in program mode. [0] ******,  [1] *****.* to [4] **.****
0.3 sec (settable from 0.1 to 9.9 sec)
5ppm ± 1 digit
– IND Pulse Input Indicator
[Single-phase pulse] Flashes at falling edge of pulse High-speed pulse lights up continuously
[UP/DOWN signal] Flashes at falling edge of UP/DOWN signal.   Flashing at falling edge of UP/DOWN signal
[Phase A/B signal] Flashes at the rise/fall edges of phase A and B.   Continuous lighting with high-speed pulses
– HI: HIGH comparator output ON
– LO: LOW comparator output ON
USB
communication
Communication specification
Communication function
Output update time
USB2.0 (Serial port communication by USB virtual COM 230.4kbps)
Writing/reading of set values/continuous output of measured values
1 to 9999.9ms, settable in 0.1ms increments (No output when output update time is set to 1 to 9)
General
Information
Operating temp./humidity
Power supply voltage

Power consumption
Isolation
Withstand voltage
Weight

-10°C to +50°C / 35 to 85%RH (non-condensing)
SPD-4801-AF: AC100-240V (Maximum rated AC85-264V) 50/60Hz
SPD-4801-DF: 12-30V DC with reverse connection protection
3W or less
Power Supply/Other Input/Output
Power supply/other input/output: 500V DC between each terminal for 1 minute
Approx. 340g
CAN Option Communication specifications
Communication function
Setting item
Output update time
CAN2.0B 10 k / 20 k / 50 k / 100 k / 250 k / 500 k / 1M bps, [Format] INTEL/MOTOROLA, [Frame] 11bit/29bit
Writing/reading of set values/continuous output of measured values
CAN transmit ID, CAN receive ID
1 to 9999.9 ms (settable in 0.1 ms increments)
(When output update time is set to 1 to 9, instantaneous values are output every 1 ms.)
RS-485
communication
option
Number of connected units
Communication format
Communication method
Communication standard
Communication speed
Data format
Communication code
Communication function
32 units (max.)
2-wire multi-drop serial communication
Asynchronous
RS-485
9,600 /19,200 /38,400bps Set in program mode
Start bit: 1 bit / Stop bit: 1 bit / Data length: 8 bits / Parity bit: None
ASCII
Writing/reading set values/measurement value output (response to request command)
Modbus RTU support is available upon request.
Analog
output option
Output signals
D/A conversion method
Output resolution
Load resistance
Output accuracy
Temperature fluctuation
Output scaling
Output update time
Input/output delay time
[E1] 0 to 10 V, [E5] 0 to 5 V, [R1] ±10 V, [R5] ±5 V, [I1] 4 to 20 mA    [Select a model]
DAC conversion method
16bit (50,000 or more)
[Voltage output] 4.7kΩ or more / [Current output] 300Ω or less
[Voltage output] ±0.1% of FS @ 23°C / [Current output] ±0.1% of FS @ 23°C
±200ppm/℃ or less
Arbitrary scaling is possible by full scale and zero scale settings
0.1 to 9999.9ms settable in 0.1ms increments
Output update time + analog rise time 150 μs max.
Alarm
[Comparator] output option
Setting method
Number of outputs

Output form

Output load voltage
Output logic

Update time

Set in program mode
2 points (or 1 point) Depends on model selection conditions.
1 point for line driver input and analog output with comparator output specification.

Isolated non-contact output (photo-MOS relay) No polarity.
When comparator operating condition is ON, resistance between COMP and COM
50 Ω or less for C2 option (2 comparator) / 100 Ω or less for C1 option ( 1 comparator)

Peak AC/DC280V 100mA (resistive load) / ON resistance 50Ω or less
Comparison is made with polarity (0 is greater than minus)
[Over] ON when set value or more / [Under] ON when set value or less

Depends on analog output update time setting. Response time 1ms (max)
.
.
.
.