0865 735 110

SY-CLAMP TAEDO SYSTEM

It has a single acting cylinder structure and is operated by hydraulic pressure when clamping, but it is returned by spring when clamping.

The pressure is the first pressure increase in proportion to the cylinder area at the operating pressure, and the second pressure is boosted by the lever.

CYLINDER is in surface contact with the mold for excellent clamping force.
tructure

Mold fastening
Mold fastening
Mold release
Mold release
Nominal method

SY ①T – ② – A

Tightening force

2 2 TON
4 4 TON
6 6 TON
10 10 TON
16 16 TON
25

25 TON


Mold height : H(mm)

Modalities
Modalities / Forms

SY-2

SY-4

SY-6

SY-10

SY-16

Interanal pressure ( Kgf/㎠ )

275

Maximum applied pressure ( Kgf/㎠ )

185

Cohesion (TON)

2

4.2

6

10.5

16.8

Stroke (mm)

5

5

7

8

8

Required oil quantity (㎖)

5.6

11.7

24.2

46.7

74.8

Applied temperature scope (℃)

-5 ~ 60℃

Oil used

General hydraulic oil

주① Weight (Kgf)

1.2 2.2 3.5 6.4 12.2
※ 주① Weight H = 100 mm

Measurement

Form a b d E F G N I J MIN. K MIN. M flux (㎖)
UNCLAMP CLAMP
SY- 2 2 3 18 42 58 49 10 12 38 8 12 5.6 4.3
SY- 4 2 3 25 60 73 56 17.5 13 59 10 17 11.7 7.5
SY- 6 2.5 4.5 30 72.8 88 64 17.5 5 64 14 20 24.2 15.6
SY-10 3 5 40 95 108 77 20 15 79 17 28 46.7 9.2
SY-16 3 5 50 120 146 86 20 15 89 20 32 74.8 46.7

.
.
.
.