| Input parameters | |
|---|---|
| Main circuit power supply | three-phase 200 to 230 VAC |
| Permitted main circuit power supply voltage fluctuation | -15..+10% |
| Rated main circuit AC power supply frequency, Hz | 50/60 |
| Control circuit power supply | single-phase 200 to 230 VAC |
| Permitted control circuit power supply voltage fluctuation | -15..+10% |
| Rated control circuit AC power supply frequency, Hz | 50/60 |
| Output parameters | |
| Applicable servomotor maximum capacity, kW | 0.5 |
| Continuous output current, A | 3.8 |
| Maximum output current, A | 11 |
| Frequency response, Hz | 1600 |
| Speed Control Range | |
| PM Closed Loop Vector (CLV/PM) | 1:5000 |
| Inputs, outputs, interfaces | |
| Analog outputs | 2 Analog Monitor ±10 VDC 16 bit |
| Communication on board | RS-422A |
| Interface | analog voltage/pulse train reference |
| Supported feedback | Incremental/absolute linear scale |
| PC connection | miniUSB – USB1.1 standard (12 Mbps) |
| Safety input | /HWBB1, /HWBB2: Baseblock signal for power module |
| Safety output | EDM1: Status monitor (fixed output) of built-in safety circuit |
| Supported motor type | for linear servomotors |
| Dimensions and weight | |
| Weight, kg | 1.5 |
| Enclosure and design | |
| Enclosure | IP10 |
| Regenerative resistor | built-in or external |
| Mounting type | base-mounted |
| Environmental parameters and standards | |
| SIL (Safety Integrity Level) | SIL2 |
| Ambient temperature (min) | 0 |
| Ambient temperature (max) | +55˚C |
| Maximum humidity (non-condensing) | 90% |
| Standards compliance | UL508C, EN50178, EN55011/A2 group1 classA, EN61000-6-2, EN61800-3, EN61800-5-1, EN954-1, IEC61508-1 to 4 |
| Vibration resistance, m/s2 | 4.9 |
| Shock resistance, m/s2 | 19.6 |