| Type | Daily | ||
|---|---|---|---|
| Synchronous motor | Quartz motor | ||
| Operating time deviation *1 Voltage influence and temperature influence |
±3 min max. | ||
| Setting error *2 | ±3 min max. | ||
| Cyclic error | ±3 min max. | ||
| Power interruption backup time | — | 180 h min. *3 | |
| Insulation resistance | 100 MΩ min. (at 500 VDC) | ||
| Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and non- current-carrying metal parts and between control output and operating circuit) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) |
||
| Vibration resistance |
Destruction | 16.7 Hz with 2-mm single amplitude for 1 hour each in three directions | |
| Malfunction | 10 to 55 Hz with 0.25-mm single amplitude for 10 minutes each in three directions | ||
| Shock resistance | Destruction | 1,000 m/s2 5 times each in 6 directions | |
| Malfunction | 200 m/s2 once each in 6 directions | ||
| Life expectancy | Contacts: 10,000 operations min., Motor: 20,000 h | ||
| Weight | Flush-mounting model: Approx. 150 g, Surface-mounting model: Approx. 200 g | ||
| Case color | Light gray (Munsell 5Y7/1) | ||